Ex Pressurised Enclosures

  • The SPZ range of ex pressurised enclosures is available in different sizes and designs. All enclosures are certified for use in ex hazardous areas (Zone 1/21 and Zone 2/22).

    Ex Pressurised enclosures allow the installation of non ex-components directly in the hazardous area. The enclosures are certified and ready to use immediately after installation.

    The control unit works without a flushing phase and automatically starts when the gas detector has checked for potentially explosive gases. The elimination of flushing time and the use of flushing gas make´s the operation particularly economical.
Material
  • Painted steel sheet
  • Stainless steel V2A, 1.4301, 304L
  • Stainless steel V4A, 1.4404, 306L
  • Stainless steel V2A, 1.4571, 306Ti
Construction
  • Fully welded construction frame
  • Ongoing to frames in the body and lid 
Body
  • Hinged on the right side (left and right at SPZ-_07 and SPZ-_08)
  • Crotch fixed welded at SPZ-_07 and SPZ-_08
  • Doors with reinforcement frame
  • Mounting plate on the backside for customer
  • Mountingplate QMP right hand side with QUINGUARD® controller
  • Mountingplate DMP right hand side with QUINGUARD® controller
  •    Closing oft he door
  • Double mandrel 3 mm
Possible Application
  • Enclosure with HMI´s
  • Enclosure in all different sizes
  • Analyzer
  • Fill-up system
  • Dosing system
  • Painting system
  • Temperature control units
Technical data
  • IP rate: IP 66
  • Ambient temperature: -25C up to +70 ?C
  • Switching capacity: max. 5 A (without contactor SC)
Pressurised Enclosure

Atex Certified, Zones 1, 2, 21, 22
II 2G Ec IIC & II 2D Ex IIIC

Standard cabinets ( W * H * D in mm):
•     SPZ-_S01  400x600x300mm  145 Watt
•     SPZ-_S02  600x600x300mm  190 Watt
•     SPZ-_S03  600x800x300mm  235 Watt
•     SPZ-_S04  800x1000x300mm  347 Watt
•     SPZ-_S05  800x1200x400mm  456 Watt
•     SPZ-_S06  800x1500x400mm  545 Watt
•     SPZ-_S07  800x1800x400mm  634 Watt
•     SPZ-_S08  1000x2000x500mm 898 Watt
•     SPZ-_S09  1200x2000x500mm 1028 Watt

Certificates
ATEX, GOST TC - RU

Marking
Ex II2G / IID

Power supply:

DC 24 Volt
AC 115 Volt 50/60 Hz
AC 230 Volt 50/60 Hz

Options:

- Certified control functions
- Certfied contactor series SC
- Variable enclosure dimension
- Door Lock
- Safety Glass Windows
- Foils in door for mounting terminals
- Double Gaskets


Components used in these pressurised enclosure systems:

 

*  QPU Controller
The QPU controller monitors air pressure within the pressurised enclosure, cabinet or device. Once the cabinet or enclosure pressure builds up it allows the non ex devices to be activated.

*  Gas Detector
This preset gas detector measures gas within an enclosure. If no gas detected, the QPU Controller is activated.
  
*  Leakage valve controller
Designed to work with the QPU Controller, this automatically compensates for leakage in pressurised enclosures.

*  PRE Pressure Regulators

Diaphram pressure regulator controls input pressure to a constant working pressure.

*  Interface module
Designed to seperate active cables like RJ45, USB or directly via terminal. Shuts off active datalines within the enclosure if pressure is lost.
QuinGuard  